Cat6a Patch Cords

Cat6a Patch Cords

Home > Products > Copper Systems > Copper Patch Cords > Cat6a Patch Cords
  • 6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue

  • 6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue

  • 6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue

  • 6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue

6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue

Description:

6in (0.15m) Cat6a 26AWG Snagless Shielded (S/FTP) PVC CM Ethernet Network Patch Cable, Blue

Features:

Product Highlights

Exceed ANSI/TIA-568.2-D Category 6A and ISO 11801 Class EA Standards
Up to 550MHz with 10G-T Speed, Support PoE/PoE+/PoE++ (IEEE 802.3af/at/bt)
S/FTP Cable Minimizes EMI and RFI Interference
24K 50μ'' Gold-plated Contacts, Resistant to Oxidation, Stable Transmission, Frequent Plugging and Unplugging, Longer Lifespan
>99.95% Oxygen-free Copper Conductors with Stable Transmission Performance
See more

Specifications

Specifications
Cable Type
Cat6a Snagless
Shielding Type
Shielded (S/FTP)
Cable Jacket
PVC CM (Round)
Length
6in (0.15m) (Including Plugs)
Conductor Material
>99.95% Oxygen-free Copper
Conductor Type
Stranded
Data Rate Support
10GBase-T
Maximum (Tested) Frequency
550MHz
Gauge (AWG)
26 (7/0.16mm)
Cable Outer Diameter (mm)
6.2 ± 0.3
Max Transmission Distance
100m
Twisted Pairs
4 Pairs
Wire Scheme
T568B, Straight
Standard
ISO/IEC 11801, ANSI/TIA-568.2-D 
Plug Type
8 Position
Support FSWireNet
No
Operating Temperature
-20 to +75°C (-4 to 167°F)
Installation Temperature
-10 to +50°C (14 to 122°F)

Detailed

Cat6a Snagless Shielded (S/FTP) Ethernet Network Patch Cable, 26AWG, 10GBase-T

Cat6a network patch cable is the cost-effective solution for indoor data center applications, supporting up to 10GBase-T and 550MHz within 100 meters of cable. And it is fully backward compatible with all the previous categories. All patch cords shall be compatible with both T568B wire scheme and passed Fluke Channel Test. The FS cat6a patch cables conductor apply oxygen-free copper with high electrical conductivity and low signal transmission attenuation. The shielded patch cord provides superior alien crosstalk (AXT) suppression and protects critical data from electromagnetic and radio frequency interference (EMI/RFI). Stranded copper patch cable can be used with a longer flex-life. Tested and verified to meet Cat6a component requirements for ANSI/TIA-568.2-D and ISO/IEC 11801 standards.

Inquiry

Message Box

  • Product Name:  

  • Your Name:  

  • Contact Number:  

  • Email Address:  

  • Message Content:  

Welcome to our online message section!

Please fill out the form on the left; we will contact you as soon as we receive your message.

Contact Us