  • Customized Cat6a Snagless Shielded (S/FTP) PVC CM Ethernet Patch Cable

  • Customized Cat6a Snagless Shielded (S/FTP) PVC CM Ethernet Patch Cable

  • Customized Cat6a Snagless Shielded (S/FTP) PVC CM Ethernet Patch Cable

  • Customized Cat6a Snagless Shielded (S/FTP) PVC CM Ethernet Patch Cable

Customized Cat6a Snagless Shielded (S/FTP) PVC CM Ethernet Patch Cable

Description:

Customized Cat6a Snagless Shielded (S/FTP) PVC CM Ethernet Patch Cable

Features:

Product Highlights

Exceed ANSI/TIA-568.2-D Category 6A and ISO 11801 Class EA Standards
Up to 550MHz with 10GBase-T Speed, Support PoE/PoE+/PoE++ (IEEE 802.3af/at/bt)
100% Factory Tested for Cat6a Patch Cord Performance
S/FTP Cable Minimizes EMI and RFI Interference
24K 50μ'' Gold-plated Contacts, Resistant to Oxidation, Stable Transmission, Frequent Plugging and Unplugging, Longer Lifespan

Specifications

Specifications
Cable Type
Cat6a Snagless
Shielding Type
Shielded (S/FTP)
Cable Jacket
PVC CM (Round)
Twisted Pairs
4 Pairs
Conductor Material
Oxygen-free Copper
Conductor Type
Stranded
Data Rate Support
10GBase-T
Maximum (Tested) Frequency
550MHz
Gauge (AWG)
26 (7/0.16mm)
Cable Outer Diameter (mm)
6.2 ± 0.3
Wire Scheme
T568B, Straight
Standard
ISO/IEC 11801, ANSI/TIA-568.2-D
Operating Temperature
-20 to +75°C (-4 to 167°F)
Installation Temperature
-10 to +50°C (14 to 122°F)
*Note: Minimum order quantity is required. Please contact your account manager for detailed information.

Detailed

Customized Cat6a Snagless Shielded (S/FTP) Ethernet Network Patch Cable, 26AWG, 10G Base-T, Fluke Patch Cord Testing

Cat6a S/FTP patch cable features 26AWG shielded twisted pair stranded copper cable with a high-performance modular plug at each end. The shielded patch cord provides superior alien crosstalk (AXT) suppression and protects critical data from electromagnetic and radio frequency interference (EMI/RFI). The snagless design protects the locking clips on the RJ45 connectors from being damaged or snapped off during installation.It exceeds the performance of the Cat6a Ethernet network cable standard and offers a cost-effective solution for indoor Gigabit Ethernet data center applications, supporting up to 10GBase-T and 550MHz within 20 meters of cable. All patch cords shall be compatible with both T568B wire schemes and pass the Fluke Patch Cord Test and Channel Test. Stranded copper patch cable can be used with a longer flex-life. The cable supports PoE to save you the expense and effort of powering PoE devices individually. You can also install PoE devices in locations distant from power outlets, such as high on walls, ceilings or poles. Variety of cable colors and lengths to meet individual requirements and system flexibility.